Testing shall be performed at any.
Blower door test form.
Where required by the code official testing shall be conducted by an approved third party.
Before the certificate of occupancy will be issued.
The attached blower door test form is to be completed by the tester.
Exterior windows and doors fireplace and stove doors shall be closed but not sealed 2.
The following will help you conduct your.
The person with that bdt number is the one that must perform the test.
Blower door test requirements form attention contractors and or owner builder.
Blower door testing is a requirement in the florida building code for residential units.
Approved we will email you a blower door tester bdt number to be used when completing the blower door test form.
Blower door tests are performed by trained and certified energy auditors but a homeowner can conduct a mini test to help pinpoint leaky areas of the home.
Please note the bdt number is issued to an individual not a company except if you are a florida licensed mechanical or class a or b air conditioning contractor.
The blower door test form is required to be signed by the license holder or the certificate holder.
The blower door test form is to be provided to the okaloosa county dept.
Residential air leakage blower door testing for florida code compliance b 75 r1 fsc cr 204 1 september 201 disclaimer.
This piece is intended to give the reader only general factual information current at the time of publication.
The blower door test simulates wind blowing against a building at 20 miles per hour in which case the total volume of air within the house would be exchanged with outside air 7 times.
Testing shall be conducted with a blower door at a pressure of 0 2 inches w g.
The 20mph wind is equivalent to 50 pascals pa of pressure difference.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
Where required by the code official testing shall be conducted by an approved third party.
Testing shall be conducted with a blower door at a pressure of 0 2 inches w g.
Dampers shall be closed but not sealed including exhaust intake makeup air backdraft and flue dampers 3.
Interior doors shall be open 4.
Holtkamp heating a c inc.
Door window seals in place blower door testing timing 2009 iecc section 402 4 2 1 requires that 1.
Blower door test during a home energy audit.
Piece is not a substitute for professional advice and should not be used for guidance or decisions related to a specific design or.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
Any applications submitted after july 1 2017 shall have blower door testing per florida building code energy conservation r402 4 1 2 as part of the inspection process.